0.7.0
Release on GitHubThis release checks the current and power on a board: a microcontroller pin asked to drive more than it is rated for is flagged, tracks, vias and thermal spokes are checked against the current they carry, and a heat map shows where the copper works hardest. The agent can copy a block you already built in another project into the open design, give an enclosure a clear window, and swap pins and gates, including an ATtiny85’s GPIO pins, to untangle the board. Parts can be marked do-not-populate, test points go on the power rails, and the design document can be downloaded as a file.
Checks
- A microcontroller pin asked to drive more current than it can is flagged. An LED or relay coil wired straight to a GPIO used to pass the checks, even when it draws 30 mA from a pin the datasheet rates for 12 mA. Now, where a part’s card gives a pin’s maximum current and the net it drives has its loads stated (
set_net loads), the new checkSEM.PIN_CURRENTnames the part, the pin, the current and the limit, and says what fixes it: a transistor or driver between pin and load, or less current. It is a warning over the limit and an error over twice it. Datasheet import now reads the per-pin current where the datasheet states one, and the bundled ATtiny85’s I/O pins carry their 40 mA. The part card’s Max column shows it. Pins without a stated limit are not checked, and supply rails stay with the existing current checks.
Layout
- The agent can swap an ATtiny85’s GPIO pins to untangle the board, without moving a signal to a pin that cannot do its job. Swaps were offered for op-amp channels and resistor arrays only. Now the bundled ATtiny85 knows what each of PB0–PB4 can do, from its datasheet’s pin table (SPI, I²C, ADC, timer outputs, the crystal), and the agent records what each net uses: plain on/off,
SCL, an ADC input. A swap that would put, say, the I²C clock on a pin without it is refused with the reason, and a net whose use is not recorded stays where it is. The reset pin, VCC and GND never move. As with every swap, it comes to you as a change to review; the firmware’s pin numbers change with it.
Part import
- A datasheet that cannot be imported now says why and what to try next. When a datasheet link led to a product page instead of the PDF, the import said only that it was not a PDF. Now it gives the page’s title and, where the page links to a PDF, that link, so the agent can try it. A file that starts like a PDF but cannot be opened (a damaged or cut-short download) is reported as such, with the advice to download it again or download it in a browser and attach it. A scanned datasheet without a text layer is named as one: the import and
read_datasheettell the agent to read its pages as pictures instead of calling it unreadable.
Projects
- Switch to a recent project in one click (Settings → General → Recent). Moving between two designs used to mean picking the file again with Open file… every time, and the app did not show which projects you had opened. Now the last 8 projects you opened are listed under Open file…, most recent first, without the one that is open; click one to open it. A project whose file is no longer in the projects folder (moved, renamed or deleted outside the app) is shown greyed out. A project renamed in the app keeps its place in the list.
Power
- The agent can show you the whole power tree in one answer. Before, what feeds what came out piece by piece: the power checks, the current check and the linear regulator heat check each looked at their own part of it. Now ask the agent “what feeds what, and will anything run hot?” and it reads
get_power_tree: for every supply rail, where its power comes from (a regulator, a connector, a battery, or unknown), the ferrites, fuses and resistors between, the rails it feeds, its loads and its current against its maximum current. For a linear regulator it also gives the heat, for example 0.85 W where a SOT-23 sheds 0.29 W, the same numbers asSEM.LDO_DISSIPATION. A rail without a maximum current or stated loads shows its current as unknown, never as fine.
Enclosure
- You choose how far apart the opened enclosure is drawn. The Enclosure view’s Opened lifted every piece by the whole box’s height and 10 mm, so a box of five pieces stood so tall that each piece was a speck. Opened now draws the pieces a third as far apart, and a slider next to Closed / Opened sets the distance, shown in mm; the app remembers it.
- An enclosure can have a clear window, and the 3D view shows what is behind it. A box with a window in front of an LED or a display, such as a bike lamp’s lid, used to show the window as solid as the rest of the box, so neither you nor the agent could see the LED behind it. Now the agent can make the window a piece in clear filament (
material: 'clear'in the script’s inlays), and the Enclosure view and the agent’s pictures draw it see-through, with the LED and the board behind it in view. In the 3MF it is a part of its own in the lid’s object, as an inlay is: give it the clear filament in your slicer.
Design document
- The design document can be downloaded as a file. Until now it only came out through the browser’s print dialog, and where that dialog did not open or was closed by mistake there was no other way to get it. Now Download ⤓, next to Design document (print / PDF) in the Layout view’s panel, saves it as one HTML file named after the project (
<project>-design.html), with the 3D pictures of the board inside it. It opens in any browser, offline, and prints from there the same way, to paper or to PDF.
Agents
- The agent can copy a block from one of your other projects into the open design. Before, the agent could list another project’s blocks but had to rebuild the one you wanted part by part. Now it copies the block in one step (
import_block): the parts with their values, the nets inside the block, the block’s title and text, and its notes and drawing order. Each net that leaves the block must first be joined to a net of your design (for example the old project’s +5V to VBUS); if one is not, or a part is in neither your library nor the old project’s file, nothing is copied. Reference designators and net names that are already used get the lowest free number instead (R1 becomes R2 if your design already has an R1). The agent is told which values to check again because they were chosen for the old board, for example a resistor on a regulator’s FB pin. The copy is one change like any other: you review it and can undo it. - The agent can look at the blocks of your other projects. Every new board used to start from scratch: a USB-C input, a charger or a 3.3 V buck you had already built and checked in an earlier project was worked out again from the datasheets. Now the agent can ask for another project’s functional blocks by name (
list_blocks) and gets each block’s parts with their values, the nets inside it and the nets it connects to the rest of the board (supplies such as +5V, signals to other parts). It only reads that project, from the projects folder, and changes nothing. Copying a block into the open design comes in a later release; for now the agent can rebuild it from the list. - An agent can show you its plan before a larger task (Settings → General → Plan step, off by default, set per project). With a long run from Claude Code or another coding agent in a terminal, a wrong early choice used to surface only when you reviewed the finished work, for example a placement with the connector on the wrong side. Now, with the plan step on, the agent first posts a numbered plan in the chat for any task that adds more than about 10 parts. You accept or reject it, with an optional comment such as “USB on the right edge”, and the agent starts only once you accept. The agent answering the in-app chat does not use it yet.
Assembly
- Parts can be marked do-not-populate (DNP). Ask the agent to leave a part off the assembly, such as a 0 Ω strap, a spare pull-up or a matching network left open, and to fit it again later. Before, every part in the design was bought and assembled. Now a DNP part stays on the board with its pads and tracks, so you can still solder it by hand, but it is left out of the BOM and the pick-and-place file you upload, and out of the stock and cost checks. The schematic shows “DNP” under its value. The Layout’s 3D view leaves a DNP part out, so you see its bare pads and holes as the assembled board will have them. A DNP capacitor or resistor no longer counts for a datasheet requirement, so leaving off a decoupling capacitor or a pull-up is reported.
Schematic
- The agent can suggest pin and gate swaps that untangle the board. On a board where an op-amp’s channel A was wired to a connector on its B side and channel B to the other, the agent could only turn and shift the small parts round it, and the crossing connections stayed. Now when it asks for suggestions at an open connection or a part, it also tries the swaps the part’s card allows (an LM358’s two channels, the four resistors of an array) and offers those that make the connections shorter or cross less, with the numbers before and after. A swap changes the schematic, so it is marked as a schematic change and comes to you for review like any other change; route again after applying it.
- A 4-resistor array in the library. Resistor array 4× (RN, 0603×4 convex, the size of 4D03 or YC164 parts) has four isolated resistors of one value; whole resistors, and the two ends of one, can be swapped.
- The agent can swap the two channels of a dual op-amp. Before, moving a signal from channel A to channel B of an LM358 took a disconnect and a connect for each of its three pins, and nothing stopped a half-done swap such as only the + inputs. Now one change swaps a whole channel: its + input, − input and output nets change places together, and the schematic and the board follow. The agent may only swap what the part’s card declares interchangeable, so it refuses to swap, say, an input with the supply pin or pins of two different parts. It is part of the changes you review. Only the LM358 and the new resistor array declare swappable pins so far.
- A linear regulator that would run too hot is flagged. A 5 V → 3.3 V LDO in a SOT-23 feeding 500 mA burns 0.85 W, about three times what that package sheds, and it passed every check. Now the checks work out each linear regulator’s loss, (Vin − Vout) × the output rail’s current, and compare it with a typical limit for its package (SOT-23 about 0.3 W, SOT-223 about 1.1 W, DPAK about 1.4 W, at 25 °C ambient): an error over twice the limit, a warning over it, with a bigger package, a buck converter or less current as the fix. Where the rail has no current set, or the package is not one the check knows, it says the loss is unknown rather than letting it pass, so set the rail’s current (the agent does this). The limits are typical figures, not your part’s datasheet: a large copper area under the tab does better. The check is
SEM.LDO_DISSIPATION. - Colour themes for the schematic (Settings → Appearance → Schematic colours): Pale yellow, Navy on cream, Green on black, Blueprint and Black on white, besides following the app’s light or dark. A theme colours only the schematic canvas: wires, symbols and their fill, text, net labels, supply symbols, the sheet and its frame. Printing and the design document stay black on white; the agent’s pictures of the schematic show the theme you see.
Sourcing
- A part search that finds nothing says whether the house lists the part at all. Searching JLCPCB for a part it has none of in stock, such as a supercapacitor, used to answer only “no parts in stock”, and the agent could not tell an empty shelf from a part JLCPCB never carries. Now it names the matching parts JLCPCB lists with no stock (its supercapacitors are seven 2.5 V parts, none in stock), or says JLCPCB lists none under those words, and suggests what to do next: other words, another assembly house, or a part you buy and fit by hand (marked DNP). A capacitor search of 1 F or more now asks for “5F”, not “5000mF”.
- Parts that only JLCPCB’s Standard assembly takes are named. JLCPCB marks some parts “Standard only” (WS2812-type LEDs, some electrolytic capacitors), and one such part sends the whole order to Standard: a higher setup and stencil fee, and a loading fee for every part number, not only the Extended ones. The cost check used to price these orders at the cheaper Economic service anyway: a 2-board order estimated at $80 was billed $133. Now Economic says it cannot take the order and names the parts. The stock check tags them “Standard only” and prefers replacements that Economic takes. The cost check says what replacing them would save and names a like-for-like part where it finds one.
- The stock check no longer reads as an all-clear when nothing could be checked. With no LCSC numbers on any part, the agent’s stock check at JLCPCB said “0 part number(s) fine to order”. Now it says how many parts have no part number and that the order can’t be checked yet; when only some parts have one, it also says how many have none.
Board
- A hand-made land pattern that doesn’t line up with itself is reported. When the agent builds a module’s footprint pad by pad from the datasheet, it can misread a dimension. In one case it moved the top and bottom pad rows of an ESP32-C3-MINI-1 but left the side pads and the centre pad where they were. Nothing in 4k7 noticed, and only JLCPCB’s footprint check stopped the order. Now a footprint with pads on all four sides (QFN, QFP, LGA modules) whose side columns aren’t centred between its top and bottom rows (or the rows between the columns) gets a warning,
XCHK.LAND_OFF_CENTRE. It names the part, the pads that are off and by how much (“the left column (pads 1–11) is centred 0.7 mm above the midpoint between the top and bottom rows”). The agent then reads the land pattern again and corrects the footprint. - 3535 power LEDs and JST XH connectors have packages. Asked for a 3.5 × 3.5 mm power LED (the Cree XP-E/XP-G class) or a JST XH connector, the agent was refused, because no package had those names, and it had to guess. Now
3535orLED-3535gives an LED the usual 3535 land pattern: anode and cathode strips with an isolated thermal pad between them. Check it against your LED’s datasheet, because a few makers put the cathode on the other side.JST XH,JST-XH-2,B2B-XH-Aand KiCad’sJST_XH_…names give a connector the 2.5 mm through-hole footprint, with the housing drawn as its outline. When a package name is still unknown, the refusal lists the closest known names. - Power tracks keep their width up to the pin: the router now runs a power net, or a net whose width you set (
set_net track_mm), at that width all along, and narrows it only in a short neck of about a millimetre right at a pad too small for it, such as a QFN or SOT-23 pin. Until now one such pad made the whole connection narrow: a 0.5 mm supply track to a QFN pin was laid at the 0.25 mm signal width for its full length, 11 mm on a test board, where it is now 0.5 mm for all but the last 1.2 mm. Boards routed with an earlier version are routed again the first time you open their layout. DRC.NECKalso names a track that stays narrow for longer than a neck: a narrow track that ran into a small pad was let be however long it was. Now only a short neck right at such a pad is. For a track the router laid, the warning tells the agent to make room there (move or turn the parts in the way) and route again, not to lower the net’s width.
Board layout
- The board now checks power tracks and plane vias against the net’s current. Before, a net’s maximum current only gave a suggested track width, for 1 oz outer copper, and nothing checked the copper as it was laid. A 0.25 mm track on a 2 A rail, a rail on an inner layer of thinner copper, or a pour on top joined to a plane by a single via all passed without a word. Now every track of a net with a maximum current is checked against that current, using its layer’s copper from the stack-up. Vias are checked where they are the only way the net’s copper crosses between two layers. The Issues list shows
DRC.CURRENT_UNVERIFIEDfor tracks andDRC.VIA_CURRENTfor vias. Each is a warning, or an error when the copper carries less than half the current. The check counts the whole current everywhere on the net, so a short branch to a pull-up can be flagged that in fact carries little; the message says so. A supply or ground net without a maximum current shows asDRC.CURRENT_UNKNOWN(info) and is never reported as fine. The agent reads all of this withget_current_map. How much the copper may heat is a new board rule, 10 °C by default; ask the agent for 20 or 30 °C on a dense board. The width the Inspector suggests for a net’s current now uses the board’s outer copper and this rule. - A heat map shows how hard the current works the power copper (Layout → layers → Current · heat map). The current check above was only a list of findings; where on the board the narrow piece or the lone via was, you had to look up by coordinates. Now the layout view can colour each power track by how much it would heat at its net’s maximum current, against the board’s allowed rise: blue and green well under it, yellow up to it, orange up to twice, red beyond (a 0.25 mm track on a 2 A rail, about +66 °C against 10 °C, is red). A track that is too narrow for the whole current, where nobody has said that much flows there, is dashed in its colour, with a “?” in its tooltip; a supply or ground net without a maximum current is grey and dashed, never blue. Vias that are the only way between two layers get a ring in the same colours with their count. Signal tracks are faint; pours and planes keep their layer colour, as their current is not worked out yet. Hover a track for its net, width, copper, current, the width it needs and its estimated heating. The map turns on by itself while a current finding is open in the Issues list; switch it off and it stays off until you reload. The agent’s pictures of the board show it too, so it can look at a spot after widening a track.
- The agent can size a track or vias for a current with the same numbers the check uses. Before, the agent could only guess a width from a rule of thumb and find out after routing whether the current check agreed. Now its calculator gives the width a current needs on a given layer of your stack-up (a 2 A rail needs 0.8 mm on 1 oz outer copper and 1.8 mm on the 15.2 µm inner layers of JLCPCB’s 4-layer boards), the current a width carries, or how much it heats, at the board’s allowed rise, and how many vias of a given drill the current needs. The answer is what the current check will say.
- Say what each pin draws, and the current check follows the current where it really flows. The current check counted a net’s whole maximum current in every track, so on a 2 A rail the 0.25 mm branch to a pull-up was flagged as unverified next to the real problems. Now the agent can state what the pins on a net draw, from their datasheets (
set_net loads, for example 1.8 A into a regulator’s input and 1 mA into a pull-up); vias it placed at a pad for a given current count too. The board then works out how the current divides over the net’s copper, from where it comes in to each pin: the branch to the pull-up carries its milliamp and passes, and a track too narrow for the current that really flows through it shows asDRC.TRACK_CURRENT(a warning, or an error over twice what it carries), with the width it needs. Where the loads stated add up to less than the maximum current, the rest may flow anywhere and is still checked. A net fed from two places stays on the old check. On the heat map such copper is drawn solid in its colour, and its tooltip gives its current and the voltage drop along it. A ground net without its own maximum current is now checked against the sum of the rails’ maximum currents, when every rail has one. - The board warns when a supply rail loses too much voltage on its way to a load. The current check worked out how far the voltage drops along each track once the agent states what the pins draw, but only showed it in the heat map’s tooltip: a 3.3 V rail could lose 180 mV over a long 0.3 mm track to a 1.5 A load without a word. Now a drop of more than 3 % of the rail’s voltage from where the current comes in to a load pin shows in the Issues list as
DRC.IR_DROP(99 mV on a 3.3 V rail), a warning, or an error over 6 %. It names the pin, the drop and the tracks that lose the most on the way, and the agent’s fix widens them. The rail needs its voltage set; without one the drop is not judged, and the agent’s current map says so. Pours and planes still count as lossless, so a rail fed through a narrow neck of a pour can drop more than shown. - The board warns when a pad’s thermal-relief spokes are too thin for its current. Where a pad or via joins a copper pour through a relief (a ring with up to four thin spokes, so it can be soldered), those spokes are often the narrowest copper on the current’s way, and the current check did not look at them: a connector pin feeding 5 A into a pour through four 0.25 mm spokes, which carry about 3.5 A, passed. Now such a joint shows in the Issues list as
DRC.SPOKE_CURRENT, a warning, or an error over twice what the spokes carry, with the spoke count, their width and the current. It is only checked where the current really comes through the spokes: a decoupling capacitor on its pour is left alone, and a rail without a maximum current gets no finding. The agent’s fix drops the pad onto the pour with vias beside it, which join the pour solid, or widens the plane’s spokes. The heat map draws a ring with the spoke count round each such pad. - The 3D view no longer covers the board with orange boxes. Since 0.2.0 the Layout’s 3D view drew a faint orange box out of every connector, the way a plug needs, and they cluttered the board, most of all seen from above. Now they are off: turn them on with the plugs button at the bottom right of the 3D view when you want to check which way a connector faces. The Enclosure view still shows the way out of each connector its enclosure opens.
- Test points on the power rails. When a first board came back you had to probe 0402 pads to check a supply. Now the agent adds a test point on every power rail by default, and on any net you name (GND, a reset, a clock): a bare 1.5 mm round pad next to the part that drives the net (the regulator or inductor, the input connector), named TP1, TP2 … with
TP_<net>on the silkscreen, for exampleTP_+3V3. The pads cost nothing: they are copper only, so they stay out of the BOM, the pick-and-place file and the cost. Asking again adds none twice. A through-hole loop a probe hooks onto (generic:TP_LOOP, Keystone 5000 series) and a smaller 1.0 mm pad are in the library too. - A part attached to an inductor now stands beside it. A part the agent put at an inductor’s pin (or at another part that is itself at an IC) could end up on the far side of the board. It now goes next to that pin.
- The agent can lay one connection itself and let the router do the rest. Before, the agent could only steer the autorouter from afar (where parts go, widths, planes, vias); to say “this track goes here” it had to take over the whole board’s copper and draw every track by hand. Now, while the router lays the copper, the agent’s
draw_trackbetween two pads (for a switching loop kept tight, a high-current path, a sensitive trace kept away from noise) is laid first on every route, through the points the agent gives and on the layers it asks for, and never ripped up; the router routes everything else round it. The points move with the part they are near. Where it finds no way, the router routes that connection its own way and the board check warns withDRC.TRACK_NOT_LAID, saying why and where. Boards without such connections route exactly as before. - The agent can give a functional block an area of the board, and its parts stay inside it. Before, keeping a block together (the feedback divider by the regulator, an analogue section away from the switcher) took a dozen “keep these parts near each other” constraints, and the next automatic placement often undid part of them. Now the agent gives the block a rectangle on the board (a room), and the placer keeps the courtyards of all the block’s parts inside it, on every later placement too; the other parts are not affected. Where the room is too small for its parts, the placer puts what fits inside and the rest next to it, and the warning
DRC.ROOMnames the block and the parts left outside. The room stays until the agent removes it. - The agent can lock a net’s routed copper so later routes leave it alone. When a route gets a net right (the switching loop tight, the power path short), the next route after some other change could lay it differently. Now the agent’s
lock_copperkeeps that net’s tracks and vias exactly as they lie: every route lays them first and routes the rest round them, and locking does not mark the routing out of date. If a part is moved off locked copper, the pieces it touched are left out but stay locked, and come back when the part does; the board check warns withDRC.LOCKED_BROKENand says how much still fits.unlock_copperlets the router route the net its own way again. Where locked copper, or a track the agent laid, blocks another connection, the open connection now names that net as in the way instead of saying the pad is closed off. - The agent can have one net routed before the others, and keep a net to a layer. Before, the router took the connections shortest first, so a switching node or a clock got whatever way was left after the short signals, and it chose each track’s layer on its own. Now
set_net route_firsthas the router route that net first on every route, so it gets the short, clean ways, andset_net layermakes a net’s tracks keep to one copper layer where that is about as short: a preference, not a ban, so it still changes layer where it must (a connection drawn withdraw_trackkeeps the layers the agent gave it). Changing either routes that net again without making the routing out of date;get_netshows them. To keep copper out of an area, the keep-outs (add_keepout) already do that, and the router keeps these nets out of them too. Boards whose nets set neither route exactly as before.
Production files
- The fab zip has fabrication notes (
-fab-notes.txt): the board’s thickness and copper weights, the stack-up it was designed for with its materials, and a table of the lines at a set impedance (target, layer, width and gap, the plane each runs over). Until now the stack-up and impedances you set stayed in 4k7, and a board with a 90 Ω USB pair could be ordered without asking for impedance control. The file then says how to order at JLCPCB, PCBWay and Eurocircuits: at JLCPCB, set Impedance Control to Yes with the stack-up named in the file selected (JLCPCB reads the order form, not the file); at PCBWay, ask for impedance control and point the order’s remarks at the file; at Eurocircuits, order in the defined-impedance pool. Finish, solder mask and silkscreen colours are chosen when you order. A board with no impedance lines says so and gets no table. The design document’s Layout section shows the same stack-up, impedance table and finish. - The layout’s checks include the production files’ read-back. Since 0.6.1 the Gerber and drill files were read back and checked against the design only when you exported them or opened them in the Gerber viewer. Now the same check runs by itself a moment after the board is routed, and what it finds shows in Layout → Checks beside the DRC and in the issue count: two nets joined in the files (
FAB.SHORT), a net in pieces (FAB.OPEN), a pad with no copper (FAB.PAD_MISSING), copper joined to nothing (FAB.FLOATING). Pick one to see the spot on the board. A finding disappears when you change the copper, and comes back only if the new files still have it. The agent gets them fromget_diagnostics. - The agent can no longer propose a board whose production files have an error. An agent connected over MCP could hand you a routed board for review while Layout → Checks listed a short, an open net or a missing pad in its Gerber and drill files (
FAB.SHORT,FAB.OPEN,FAB.PAD_MISSING). Nowproposewaits for the files’ check, refuses while one of these errors is open, and tells the agent where each one is so it fixes the copper first. Copper joined to nothing (FAB.FLOATING) is a warning and does not stop it.
Fixes
- Parts you or the agent placed stay put when another part moves. Until now a part placed with place (or dragged on the board) was kept relative to the part the placer guessed it belonged with, often the main IC: when the agent moved that IC or a connector, every part placed round it moved too, and on one board the agent locked about 50 parts one by one to stop it. Now a placed part stays where it was put, with no lock needed. It follows another part only when that is said with
attach(the cap belongs with its IC). Parts the placer put down itself still move with the part they belong with. Choices saved earlier are kept where they stand the next time the part they followed is moved. - Changing a part’s value now tells the agent when its package changes, and what the bigger land runs into. Raising a generic capacitor’s voltage rating above 25 V (or its capacitance, or a resistor’s power or an inductor’s current) quietly moves it to a bigger package, for example from 0603 to 0805. On a routed board the bigger pads can then sit over or too close to a via or track that was already there, but the edit reported no new errors, and the clearance error only showed the next time the board was checked. Now the edit’s result says so, for example “C3: package 0603 → 0805 (50V rating)”. On a routed board it also lists any
DRC.SHORT,DRC.CLEARANCEorDRC.VIA_IN_PADerrors at the new pads, so the agent moves the part or routes again before it reports the board as clean. - The autorouter no longer lays acid traps of its own. Where a routed track ended on the side of another track of its net, it often met it at 45°, and Layout → Checks then warned about an acid trap (
DRC.ACID_TRAP) on copper the router had laid itself. The agent spent turns bending tracks it never drew. On a test board of the 12 V buck with 4 ATtiny85 and their LEDs, one routing left 1 such warning, and the same board with 8 ATtiny85 left 3. Now the track turns just before the join and meets the other track at 90°, so those warnings are gone, and the router makes the same connections as before. Where there is no room for that turn the join stays as it was and the warning still shows. Route the board again to get the new joins. - The autorouter no longer bends a track back on itself. Where the router cut across a bend of its path, a track could run past the bend and come back at 45°, a hairpin with a narrow wedge between its two pieces, and Layout → Checks warned about an acid trap (
DRC.ACID_TRAP) on the router’s own copper. On 300 small test boards of passives this happened once (the other 299 route exactly as before). Now the two pieces meet at 90° or wider, and the router makes the same connections as before. Where there is no room for that, the track stays as it was. Route the board again to get the new tracks. - Parts imported from a bottom-view pad drawing no longer come out mirrored. Many LED, connector and module datasheets draw the pads seen from below (“bottom view”, “pad side”). The import read every drawing as seen from above, so on a Cree XP-G3 the anode pad ended up on the cathode’s side, and nothing warned. Now the import records which way the drawing is seen and mirrors a bottom view to the top view, and the agent checks the label and the polarity mark when it reads the pads off a drawing, including when it gives a part a footprint of its own. An import whose drawing does not say which way it is seen waits for your review with a warning. Parts imported before this version keep their pads: if one came from a bottom-view drawing, compare its footprint in Parts with the datasheet and import it again if it is mirrored.
- The agent’s search for part moves that free an open connection tries moves again on a crowded board. When routing left connections open,
suggest_movesoften answered that none of 0, 1 or 2 tries closed one, so the agent learnt nothing. It kept the small parts it tried 0.3 mm from their neighbours and 2 mm from the edge, further apart than the placer puts them, so on a packed board almost every move was thrown away before it was tried. Now a move only has to stay clear of the other parts and the edge clearance, as the board’s checks ask. It also tries 2 mm shifts, diagonal shifts, and shifts combined with a turn. On a 128-part test board 81 of 402 moves now pass this first check, where 9 of 50 did; the best 12 are routed in about 10 s (15 s at most, as before). When nothing can be tried, it says why: which parts stay where they are and why (for example “U1 (a main part); J1 (locked)”), that there is no room round the parts, or that every move makes the placer shift many other parts because the placement still has overlaps to fix. - The Gerber viewer no longer says copper reaches past the board outline when it doesn’t. On a board with a copper pour, the read-back of the production files said that top and bottom copper reach 0.8 mm past the board outline, while the board view and the edge-clearance check showed all copper inside. The read-back counted the gaps the pour keeps from the board edge, which the files draw as cut-away copper along the outline. Those gaps remove copper and add none. Now only copper that is really there counts. When something does stick out, the note names the layer, the edge and roughly where (for example “at its right edge, round x 11.0, y 5.0 mm”), so you can find it in the viewer. This goes back to 0.6.0. The files themselves were always right, so you don’t need to export them again.
- A datasheet import waiting for your review no longer blocks the agent’s next import. While one import waited for review in Parts, the agent’s
import_partfor any other part was refused, and so was one while an import was running. The agent could only ask you to save or discard the first, so a design needing several new parts stalled. Now the next import is queued behind it. The agent is told what it is waiting for, and can settle the review itself (pending_import) or leave it to you. The queued import starts by itself once the review is saved or discarded. - A datasheet link that does not lead to a PDF says what came back. Some manufacturers’ links, Cree LED’s among them, answer with a web page or a 404 instead of the PDF, and the import failed with only “not a PDF” or “HTTP 404”. Now the message names the link, where it was redirected, and what came back (for example an HTML page and its title), so the agent can look for the direct PDF link. A PDF with a few stray bytes before its header is now accepted.
- The agent now sees copper shorts in its design checks. Two parts whose pads touched, or a track left lying over a pad after the part’s land pattern was edited, showed in Layout → Checks as
DRC.SHORT, but the agent’sget_diagnosticsdid not list them, so it reported a clean board and found the shorts only in the production files’ read-back (FAB.SHORT). Nowget_diagnosticslists the board’sDRC.SHORTandDRC.CLEARANCEfindings. Each names both pieces of copper, such astrack t1 (GND) touches U1.3 (not connected), and says what to do: move or erase the track, or move the part. A pad that is not connected counts as its own net, so copper over it is a short. - A pin rated lower than its part’s supply is now checked against the rail it is tied to. A part imported from its datasheet only took the supply’s absolute maximum, on its supply pins; a lower limit on another pin, such as 6.5 V on the EN pin of a 32 V regulator, only went into the pin’s text. So an EN pin tied straight to a 12 V rail went unflagged and the regulator would have failed. Now the import takes each pin’s own absolute maximum from the datasheet’s ratings table, and
SEM.ABS_MAXflags the pin when its net’s voltage is above it. Parts imported with an earlier version have no such limits: import a regulator or driver again to have its enable and logic inputs checked. - A wrong
timeout_sno longer endswait_for_revieworimport_partat once: when an agent connected over MCP passed a timeout that was not a number (such as"abc") or a very large one (over about 25 days), the server gave up straight away with “The app did not answer wait_for_review within NaN s”, and the agent never saw what was wrong with its call. Now the server waits as long as the app allows for that tool (5 to 600 s for a review, 30 to 900 s for an import), so the agent gets the app’s answer: the review, the imported part, or a message saying what is wrong withtimeout_s. This goes back to 0.1.0. - The built-in ATtiny85 (ATTINY85-20SU) has the footprint of the real part. The library gave it the narrow 150 mil (3.9 mm) SOIC-8, but the ATTINY85-20SU comes in Microchip’s 8S2 package, a SOIC-8 with a 208 mil (5.3 mm) body and leads about 7.9 mm across: on a board made with the old footprint its feet do not reach the pads (pad rows 5.3 mm apart instead of about 7.3 mm). It now has the 208 mil land and 3D body, named
SOIC-8-208milas JLCPCB lists the part. This goes back to 0.1.0. A design keeps the part as it was when the part was added, so in a design made before this version, delete its ATtiny85s and add them again, place and route them again, then export the production files again. The narrow SOIC-8 ATtiny85 is the ATTINY85-20SSU. - Renaming a project to the same name in other case keeps the name. On macOS and Windows, renaming project “lamp” to “Lamp” made it “Lamp 2”, as if another project already had the name. It now becomes “Lamp”. A project whose name really is taken still gets a number.
- A project opened from a copied file is named after that file. Opening a copy such as
bike-lamp-rev2.twd.jsonfrom outside the projects folder (Settings → General → Open file) made the project “bike-lamp 2”, named after the design inside the file, and opening a copy you had just put into the projects folder made yet another copy. Now the project is called “bike-lamp-rev2”, and a file already in the projects folder opens in place. A number is added only when another project already has that name, so no file is overwritten. This goes back to 0.2.0. A project already called “bike-lamp 2” can be renamed in Settings → General. - A project folder the app cannot read is reported once, with what to do. When the server could not read the projects folder, the message “Could not read the project files” came back every four seconds for as long as the app was open. Now it shows once (and again only if the reason changes) while the app keeps trying in the background. On a Mac, where the cause is usually that macOS keeps Documents from the program that started the server, the message says so and points to System Settings → Privacy & Security → Files and Folders.